Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Phys Med Biol ; 68(19)2023 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-37735967

RESUMO

Purpose. Commercial electron FLASH platforms deliver ultra-high dose rate doses at discrete combinations of pulse parameters including pulse width (PW), pulse repetition frequency (PRF) and number of pulses (N), which dictate unique combinations of dose and dose rates. Additionally, collimation, source to surface distance, and airgaps also vary the dose per pulse (DPP). Currently, obtaining pulse parameters for the desired dose and dose rate is a cumbersome manual process involving creating, updating, and looking up values in large spreadsheets for every treatment configuration. This work presents a pulse parameter optimizer application to match intended dose and dose rate precisely and efficiently.Methods. Dose and dose rate calculation methods have been described for a commercial electron FLASH platform. A constrained optimization for the dose and dose rate cost function was modelled as a mixed integer problem in MATLAB (The MathWorks Inc., Version9.13.0 R2022b, Natick, Massachusetts). The beam and machine data required for the application were acquired using GafChromic film and alternating current current transformers (ACCTs). Variables for optimization included DPP for every collimator, PW and PRF measured using ACCT and airgap factors.Results. Using PW, PRF,Nand airgap factors as parameters, a software was created to optimize dose and dose rate, reaching the closest match if exact dose and dose rates are not achievable. Optimization took 20 s or less to converge to results. This software was validated for accuracy of dose calculation and precision in matching prescribed dose and dose rate.Conclusion. A pulse parameter optimization application was built for a commercial electron FLASH platform to increase efficiency in dose, dose rate, and pulse parameter prescription process. Automating this process reduces safety concerns associated with manual look up and calculation of these parameters, especially when many subjects at different doses and dose rates are to be safely managed.


Assuntos
Eletricidade , Elétrons , Humanos , Frequência Cardíaca , Software
2.
Biomed Phys Eng Express ; 8(1)2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34768242

RESUMO

A 3-D dosimeter fills the need for treatment plan and delivery verification required by every modern radiation-therapy method used today. This report summarizes a proof-of-concept study to develop a water-equivalent solid 3-D dosimeter that is based on novel radiation-hard scintillating material. The active material of the prototype dosimeter is a blend of radiation-hard peroxide-cured polysiloxane plastic doped with scintillating agent P-Terphenyl and wavelength-shifter BisMSB. The prototype detector was tested with 6 MV and 10 MV x-ray beams at Ohio State University's Comprehensive Cancer Center. A 3-D dose distribution was successfully reconstructed by a neural network specifically trained for this prototype. This report summarizes the material production procedure, the material's water equivalency investigation, the design of the prototype dosimeter and its beam tests, as well as the details of the utilized machine learning approach and the reconstructed 3-D dose distributions.


Assuntos
Dosímetros de Radiação , Radiometria , Humanos , Aprendizado de Máquina , Doses de Radiação , Água
3.
Med Phys ; 45(10): e793-e810, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30226286

RESUMO

The term Big Data has come to encompass a number of concepts and uses within medicine. This paper lays out the relevance and application of large collections of data in the radiation oncology community. We describe the potential importance and uses in clinical practice. The important concepts are then described and how they have been or could be implemented are discussed. Impediments to progress in the collection and use of sufficient quantities of data are also described. Finally, recommendations for how the community can move forward to achieve the potential of big data in radiation oncology are provided.


Assuntos
Bases de Dados Factuais , Informática Médica/métodos , Neoplasias/terapia , Radioterapia (Especialidade)/estatística & dados numéricos , Mineração de Dados , Humanos , Armazenamento e Recuperação da Informação , Motivação , Estadiamento de Neoplasias , Neoplasias/diagnóstico , Neoplasias/patologia
4.
IEEE Trans Med Imaging ; 27(5): 709-22, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18450543

RESUMO

An analytic formula is derived for the sensitivity of collimators achieving transverse collimation with a slit and axial collimation with a slat assembly whose septa may be parallel or focus on a line. The formula predicts sin(3) phi dependence on the incidence angle and, in the particular case of parallel slats, 1/h dependence on the distance from the slit. More complex expressions for sensitivity that do not diverge at points near the slit or the focal line of the slat assembly are also derived. The predictions of the formulas are checked against simple cases for which solutions are available from direct calculation as well as against Monte Carlo simulation and published experimental data. Agreement is good in all cases analyzed. An approximate penetration model is also introduced: it involves the use of a sensitivity-effective slit width and septal length. Its predictions are compared to simulation results. Agreement was found to be compatible with statistical fluctuation (+/- 0.3%) for geometric sensitivity and better than 3% of total sensitivity in the worst case of septa designed for high-energy (364.5 keV) photons.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Phys Med Biol ; 53(4): 953-66, 2008 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-18263951

RESUMO

Single photon emission computed tomography (SPECT) can be performed with various collimator types, which have an inherent tradeoff between the properties of sensitivity, resolution, field of view and complete sampling. Slit-slat collimation, which has seen recent interest in the literature, combines a slit parallel to the axis of rotation of a gamma camera with a set of septa perpendicular to the slit. This collimator geometry exhibits properties that may enhance some SPECT imaging applications, specifically imaging of the breast, limbs and medium-sized animals. However, a complete description of its system response is critical for a comparison to other collimator types and for accurate reconstruction of projection data. Herein, experimental and Monte Carlo methods are used to determine the sensitivity and transaxial and axial resolutions as a function of the incidence angle theta, which is the angle formed by the line from the photon source to the center of the slit and the plane of the slit, to compare to theoretical expectations. Four configurations are investigated by varying the slit width, septal spacing and septal height. Monte Carlo sensitivity data not modeling penetration and scatter exhibit a sin(3)theta dependence. Experimental and Monte Carlo-derived sensitivity data modeling scatter and penetration are consistent with each other and have a sin(x)theta dependence, where x is greater than 3. Transaxial resolution data show a small dependence on theta, and axial resolution data are consistent with no angular dependence.


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único/métodos , Modelos Químicos , Método de Monte Carlo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Phys Rev Lett ; 93(24): 242001, 2004 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-15697795

RESUMO

We report the first observation of a charm-strange meson D(+)(sJ)(2632) at a mass of 2632.5+/-1.7 MeV/c(2) in data from SELEX, the charm hadro-production experiment E781 at Fermilab. This state is seen in two decay modes, D(+)(s)eta and D0K+. In the D(+)(s)eta decay mode we observe a peak with 101 events over a combinatoric background of 54.9 events at a mass of 2635.4+/-3.3 MeV/c(2). There is a corresponding peak of 21 events over a background of 6.9 at 2631.5+/-2.0 MeV/c(2) in the decay mode D0K+. The decay width of this state is <17 MeV/c(2) at 90% confidence level. The relative branching ratio Gamma(D0K+)/Gamma(D(+)(s)eta) is 0.14+/-0.06. The mechanism that keeps this state narrow is unclear. Its decay pattern is also unusual, being dominated by the D(+)(s)eta decay mode.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...